Supports alarm output when device is disconnected
2*WG Engress DI+2 WG Door Sensor DI+1 DI support Open All Doors function in case of emergency
Data and timer can be kept for 60 days after power down
Built-in power and data transmission LED indicators for debugging and status
63 Time Zones can be set up holidays and levels, and combine with other time zones
Each user can be set to allow to enter/exit assigned doors with 16 sets anti-pass-back function
Alternative door group control selection:cluster door group or individual door group
With 3 replay outputs
Supports Wiegand and RS-485 reader interfaces, for 14+2 door control (two RS-485 ports for 14 RS-485 readers; two WG ports for 2 WG readers)
AR-716-E16 is built with network card,for connecting to LAN or internet
Item NO. |
AR-716-E16 |
User Capacity |
16,000 Users |
Communication Interface-Host |
Host Node:1~254 |
Communication Interface-CH(Slave) |
CH1(RS485):6 or 8 Readers |
Frequency |
No |
Installation Environment |
No |
Intput |
Digital Input : 2 Egress(R.T.E.)/ 2 Door contact / 1 Fire Alarm |
Output |
Relay Output: 2 Lock Relay/ 1 Alarm Relay |
Fingerprint Template |
No |
Floors Capacity |
64 floors |
Time-Attendance |
Yes |
Weight(g) |
Metal Box: 1,754±10 |
Dimension(mm) |
Metal Box: 180(L)X231(W)X62(H) |